⚠️ UNOFFICIAL ARCHIVE — a snapshot of the former FAA Fire Safety website (fire.tc.faa.gov) as of October 2025, preserved from the Internet Archive. Historical record only; no longer updated. Not affiliated with or endorsed by the FAA. · About this archive
Please enable Style Sheets for enhanced viewing & features.

 

Search Results

Records 621 to 625 of 733

Title: Fire Extinguishing Studies of the Northrop F-89 Powerpplant
Author: Allen V. Young,
Abstract: A study was made of the control of in-flight turbojet powerplant fires by conducting full-scale tests on the F-89 fire extinguishing system. The early phases of this study showed that the F-89 fire extinguishing system was ineffective in extinguishing fires of low, as well as high, intensity. Seven modifications of this system wee tested in an effort to accomplish successful extinguishment using bromochloromthane in a perforated tubing system. Considerable improvement in extinguishment of fires was accomplished but to warrant acceptance of the system.
Report: FSR-0002 Pages: 26 Size: 1.60 MB
Title: Fire-Extinguishing Studies of the Northrop F-89 Powerplant
Author: Allen V. Young
Abstract: A study was made of the control of in-flight turbojet powerplant fires by conducting full-scale tests on the F-89 fire extinguishing system. The early phases of this study showed that the F-89 fire extinguishing system was ineffective in extinguishing fires of low, as well as high, intensity. Seven modifications of this system wee tested in an effort to accomplish successful extinguishment using bromochloromthane in a perforated tubing system. Considerable improvement in extinguishment of fires was accomplished but to warrant acceptance of the system.

A high-rate-discharge system then was considered as a possible means of providing effective extinguishment. A high-rate-discharge system, consisting of a manifold and distribution lines, was developed which effectively extinguished all fires ignited inside the engine bay, including those of a size which consumed all oxygen in the cooling air. Dibromodifluoromethane was found more effective than bromochloromethan as the extinguishing agent.
Report: Tech. Dev. Report 365 Pages: 26 Size: 1.6 MB
Title: Flame Spread Properties of Building Finish Materials
Author: Damiel Gross
Abstract: Flame-spread data, as measured by the radiant panel method, have been obtained for a wide variety of materials including representative composite assemblies of interior finishes applied to common wall base materials.
Report: FSR-0239 Pages: 5 Size: 553 KB
Title: Evaluation Of The Fire Extinguishing System On A Modified PBY Airplane
Author: Paul R. Dierdorf, James E. Damaree
Abstract: As a result of request by Region 3 of the Civil Aeronautics Administration, Kansas City, Missouri, a modified PBY aircraft, designation N19Q, was flown to the Technical Development Center, Indianapolis, Indiana, on August 19, 1957, for evaluation tests of the fire extinguishing system. Two flight tests were conducted, one under takeoff power and the other under cruise power conditions. Extinguishing agent concentrations were measured by means of the Statham Model GA-2A portable gas analyzer. This instrument is capable of recording the concentrations and duration of the discharge of the extinguishing agent while the aircraft is in flight. A recorded agent concentration of at least 15 per cent, for duration of � second or longer, is required to assure that the extinguishing system is adequate.
Report: FSR-0003 Pages: 14 Size: 2.43 MB
Title: Evaluation of the Fire Extinguishing System on a Modified PBY Airplane
Author: Paul R. Dierdorf & James E. Demaree
Abstract: As a result of request by Region 3 of the Civil Aeronautics Administration, Kansas City, Missouri, a modified PBY aircraft, designation N19Q, was flown to the Technical Development Center, Indianapolis, Indiana, on August 19, 1957, for evaluation tests of the fire extinguishing system. Two flight tests were conducted, one under takeoff power and the other under cruise power conditions. Extinguishing agent concentrations were measured by means of the Statham Model GA-2A portable gas analyzer. This instrument is capable of recording the concentrations and duration of the discharge of the extinguishing agent while the aircraft is in flight. A recorded agent concentration of at least 15 per cent, for duration of � second or longer, is required to assure that the extinguishing system is adequate.
Report: Tech. Dev. Report 334 Pages: 14 Size: 2.5 MB

Search Again

 

Choose the type of search you'd like to perform:
(Use AND or OR to refine your search)

Report Number

Report Title

Author

Keyword *

* This will only search through the Abstract of the reports.

List All Reports